Safety Screen Sheet“ZONE SAVER”

Safety Screen Sheet“ZONE SAVER”

The zone saver is a device for color-coding an objective zone apart from neighboring zones, when inspecting features of electric systems, like the electric current in switchboards, monitoring panels, and control panels. Systems may include generators, power plants, operation sections, transformer substations, and general controls.


↓For further reference

Safety Management Using ZONE SAVER Safety Sheets Instructions for Instaling ZONE SAVER Protection Sheet

SALIENT FEATURES

  1. 1/ One-touch operation allows easy delimitation by colors
  2. 2/ Scroll function allows easy setting at a desired position
  3. 3/ Outstanding fire prevention characteristics (complying with Article 4, Section 3 of the Enforcement Order of the Fire Defense Law)
  4. 4/ Outstanding antistatic property (surface-specific resistance value : 106Ω)

DIMENTIONS

Safeguarding sheet for zone display by color

Panel Width 110 Type 75 Type
350 Panel TKS110- 350 TKS75- 350
500 Panel TKS110- 500 TKS75- 500
600 Panel TKS110- 600 TKS75- 600
700 Panel TKS110- 700 TKS75- 700
800 Panel TKS110- 800 TKS75- 800
900 Panel TKS110- 900 TKS75- 900
1000 Panel TKS110- 1000 TKS75- 1000

※Select according to the board dimensions.

COLOR VARIATION

※The letters come in fluorescent red (expect for R Type). You may select from the message shown below or set your own message.

※External appearance and specifications may be changed without prior notice for improvement purposes.

Safety Management Using "ZONE SAVER" Safety Sheet

Using safety sheets of different colors for each device in panels will decrease the potential for human errors, reducing the risk of accidents, and shortening working time. That, in turn, reduces costs. “Zone Saver”safety sheets are indispensable for efficient safety management.

Installation and removal of protective materials takes excessive time.
Transport, installation and removal of protective materials increases the risk of accidents from electrical discharges,ground contact or short-circuits.
Most of the panels in the central control panel room or in the relay equipment room are installed in lines, and identification of each unit is difficult inside the panels. In addition, machines are commonly arranged into terminal blocks by machine, but actual indications are not clearly shown, which results in errors in identification of the units.
This structural arrangement increases the possibility of trouble due to unit misidentification.

Control Practice

Inspection and repair jobs are carried out frequently inside the panels. So it is necessary to carry out the following jobs in advance.

  • Protection of circuits
    inside the panel

  • Protection of components
    inside the panel

  • Protection of the surface
    of the panel

Proposal

Installation of protective sheets on the panel surface and panel interior will protect the panel and contribute to the prevention of accidents caused by mistakes in unit identification.

  • Installation of safety sheets during
    local operation inside the panel

  • Installation of safety sheets during
    local operation inside the panel

  • Installation of safety sheets on
    the surface of the panel


Instructions for Installing "ZONE SAVER" Protection Sheet

    Remove the existing nameplate/NP.BD   Install the Zone Saver

installation

  • Dimensions of nameplate/NP.DB are determined according to the Electric Power Standards of the Japan Electrical Manufactures Association. One-size for all the installation holes makes it easy to replace them.
  • Nameplate/NP.DB
    installation surface

  • Zone Saver installation
    surface

  • Installation holes on the
    frontal side of the
    nameplate

  • Installation holes on the
    frontal side the Zone Saver

  • The roll screen (electrostatic/fire preventing) is installed inside the Zone Saver Box. By pulling down the roll screen, the zone in concern can be distinguished from adjacent panels.
  • Characteristics of the sheet
    ・Easy operation, the pulling pole is used to pull down and to easily roll up the sheet.
    ・Scroll functions for setting at the required position.
    ・High transparency for accurate verification of measuring gauges and indicating lamps.
    ・Electrostatic prevention characteristics (specific surface resistance:106Ω).
    ・Outstanding fire prevention characteristics.
    (complying with Article 4, Section 3 of the Enforcement Order of the Fire Defense Law)

installation state

  • Characteristics of the product
    Clear identification of the limits of the electric distribution panels outside the operation range prevents mistakes in operation such as"wrong verification" or "wrong operation."
  • Install in place of the nameplate/NP.BD on the panel
  • Installation places
    Nuclear plants, Transformer substations, Generators, Transformers, Power plants, Switching stations, General control stations, Electric power centers, Technical centers.